Technical data
Max. immersion 7 m with 10 m cable length
Max. temperature of the liquid (sewage water) 25°C with partially submersed pump 35°C with totally submersed pump
Max. solids passage 50 - 65mm
Poles 2
Insulation class F
Protection degree IP68
Voltage Single phase 1~230V±10% Three phase 3~400V±10%
Materials
Pump body Cast iron
Impeller AISI 304 (EN 1.4301)
Shaft AISI 316 (EN 1.4401)
Mechanical seal
50DAR:
Impeller side: Graphite/Ceramic
Motor side: NBR sealing ring
65DAR:
Impeller side: SiC/Ceramic
Motor side: NBR sealing ring
Permanent split capacitor built in overload motor protector with automatic reset.
The three phase version does not have an internal motor protector, therefore
overload protection must be provided by the user.
The Part number is different
The minimum pressure these pumps require is 2 meter's, if you do not have 2 meter’s differential from water level to discharge point,or a minimum of 14 meter's horizontal run, then use a 1" bore discharge hose or your motor will burn out
What is the lowest head pressure
Part numbers have changed to harmonise along with design changes. The part number stated is the current one in use, there are different numbers for OEM products also, if you have any doubts please advise the part number and we will confirm.
Discounts
Further quantity discounts are available for this product range, call the office for details 0161 428 0133
UK Mainland Delivery is normally by next working day courier if order is placed before 1.30pm. ie despatched on Monday for Tuesday delivery. If placed after 1.30pm then the goods will be despatched the next working day. ie Monday for Wednesday delivery. Highlands and offshore deliveries differ.